Products
-
ODOT-MS100T/100G Series : 5/8/16 Port Unmanaged EtherNet Switch
MS100T
10/100 Mbps self-adaption,(Auto-MDI/MDI-X)
Supports IEEE 802.3 for 10BaseT
Supports IEEE 802.3u for 100BaseT and 100BaseFX
Supports IEEE 802.3xfor flow control
Supports broadcast storm protection
Supports working temperature: -20~70℃
5/8/16 ports unmanaged Ethernet Switches DIN-rail
-
ODOT Remote I/O Module
Flexible protocol module and I/O module plug and play, features as below:
1. Designed with a max of 32 modules, each I/O module is built with 16 channels and each have LED indicator.
2. Supports an overall of 512 I/O points and self healing;
3. The I/O module back plate cable can be extended to 15 meters to be used in multiple panels;
4. WTP is from -40~85℃ with a warranty of 3 years;
5. High speed 12M back plate bus, with 32 digital quantity modules of a refreshing period at 2ms and analog quantity is 2ms;
6. Supports Modbus-RTU, Modbus-TCP, Profinet, Profibus – DP (DPV0), EtherCAT, Ethernet/IP and others up to 12 kinds of the main stream protocol.
-
CT-5801: Terminal module
CT-5801: Terminal module
Terminal modules are used to stabilize the internal bus communication.Each C series I/O protocol adapter must be equipped with 1pc of terminal module CT-5801 no matter how many sub-modules are connected.
The dustproof terminal could cover the internal bus and field power supply hardware of the last IO module.
And terminal modules have no process data and configuration parameters.
* Take no module channel and replace CT-5800.
-
CT-2228: 8 channel digital output/24VDC/ Source type
Module features
◆ the module supports 8-channel digital output, output high level effective, and output voltage 24V
◆ the module could drive field equipment (relay, solenoid valve, etc.)
◆ the module internal bus and field output are isolated by optocoupler
◆ the module carries with 8 digital output channel LED indicator
◆ the module has the functions of thermal shutdown and overcurrent protection
◆ the module supports short circuit protection and overload protection
-
CT-623F: 8 digital input&8 digital output /24VDC/ source or sink
CT-623F: 8-channel digital input /24VDC/ source or sink type & 8-channel digital output /24VDC/ source type
Module features
◆ The module supports 8-channel digital input, and supports source type and sink type two-way input. The input voltage is 0V/24VDC.
◆ The module supports 8-channel digital output, Output high level valid, and the output voltage is 24VDC.
◆ Module input channel can collect digital output signal of field equipment. (dry contact or active output)
◆ The module input channel can be connected to the 2-wire or 3-wire digital sensor.
-
CT-221F: 16 channels digital output/24VDC/Sink type
CT-221F 16 channels digital output/24VDC/Sink type/output is 0V, the output low level is valid
Module features
◆ the module supports 16 channels digital output, the output voltage is 0V and the output low level is valid.
◆ the module can drive field equipment (relay, solenoid valve, etc.)
◆ the internal bus and field output of the module both adopt electromagnetic isolation
◆ the module carries 16 digital output channel LED indicator
◆ the module has the function of thermal shutdown and over current protection
-
CT-121F: 16 channel digital input/24VDC/ Sink type
CT-121F:16 channel digital input/24VDC/ Sink type/The input high level is valid
Module features
◆ the module supports 16 channels digital input, supports sink input, and input voltage is 24VDC.
◆ the module can collect digital output signal of field equipment (dry contact or active output).
◆ the module can be accessed to 2-wire or 3-wire digital sensor.
◆ the internal bus and field input of the module use opto-isolator.
◆ the module supports the input signal holding function, and the holding time can be set.
◆the module carries 16 digigtal input channels with LED indicator on each channel.
◆ supports counting function, by adding counting sub-module.
◆ each input channel of the module supports a 32-bit counter with the counting frequency <200Hz.
◆ the module can set the digital signal input filtering time and the byte transmission order of the counter.
◆ each channel of the module can set the counting mode and counting direction independently.
-
ODOT CN-8012: Profibus-DP Bus Adapter
CN-8012 Profibus-DP Bus Adapter
Module Overview
CN-8012 PROFIBUS-DP network adapter supports access of standard PROFIBUS-DP, and the protocol version it supports is DPV0.
-
ODOT CN-8033: EtherCAT Network Adapter
The CN-8033 EtherCAT I/O module supports standard EtherCAT protocol access. The adapter supports a Max. input of 1024 bytes and a Max. output of 1024 bytes. It supports 32 pcs of extended IO modules.
-
ODOT CN-8011: Modbus-RTU Bus Adapter
CN-8011 Modbus-RTU Bus Adapter
Module Overview
CN-8011 Modbus-RTU network adapter supports standard Modbus-RTU communication, it supports function code of 01/02/03/04/05/06/15/16/23, and this device could monitor the IO module communication state in real time.
-
ODOT CN-8034: EtherNET/IP Network Adapter
ODOT CN-8034 EtherNET/IP Network Adapter
The CN-8034 Ethernet/IP I/O module supports standard Ethernet/IP protocol access. The adapter supports a Max. input of 504 bytes and a Max. output of 504 bytes. It supports 32 pcs of extended IO modules.
-
CT-3238: 8-channel analog input
CT-3238: 8-channel analog input /0&4-20mA/15-bit single-terminal
◆ The module supports 8-channel current signal acquisition.
◆ The module can be configured for 0-20mA or 4-20mA current signal acquisition.
◆ The module supports 2-wire (non-loop output, external power supply required) or 4-wire current sensor input.
◆ The internal bus of the module and field input adopts magnetic insulation.
◆ The module input channel is connected to the field active analog signal current output sensor.
◆ The module channel equips with TVS overvoltage protection.