Protocol Converter
-
ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll or Non-standard protocol to ProfiNet Converter
ODOT-PNM02 V2.1
Modbus (master/slave, RTU/ASCII) to ProfiNET, 2 port serial port (RS485/ RS232 / RS422), supports 50 slots, 200 commands in TIA
portal (by configured software), support MAX 60 slaves
♦ Supports protocol conversion between Modbus and PROFINET
♦ Supports 2* RS485/RS232 or 1*RS422
♦ Supports Modbus master or slave, and supports RTU or ASCII
♦ Supports working temperature of -40〜85°C
♦ Supports data area: 2 serial Modbus-RTU/ASCII to PROFIBUS gateway with Max. input 1440 bytesand Max. output 1440 bytes
♦ Supports one key reset
♦ ODOT-PNM02 V2.0 supports Maximum slots: 50
♦ ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)
-
MG-CANEX CANopen to Modbus TCP converter
MG-CANEX Protocol Converter
CANopen to Modbus TCP protocol converter
MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.
As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.
-
ODOT-DPM01: Modbus-RTU to Profibus-DP Converter
♦ Supports protocol conversion between Modbus and PROFIBUS
♦ Supports RS485, RS422 and Rs232
♦ Supports Modbus master and slave, and supports RTU or ASCII
♦ Supports working environment of -40~85°C
♦ PROFIBUS-DP: Max. Input 244 bytes, Max. Output 244 bytes
♦ DPM01:1-way Modbus to PROFIBUS slave gateway, sum of input and output is 288 bytes.
-
ODOT-S4E2: 4 Serial Modbus RTU/ASCII to Modbus TCP converter
♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP
♦ Supports the connection of5 TCP clients simultaneously
♦ ODOT-S2E2 supports 2*RS485
♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422
♦ Each serial port supports Modbus masterand slave
♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway
♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway
♦ Supports one key reset
♦ Gateway working mode: Transparent transmission, address mapping
-
ODOT-S2E2: 2 Serial Modbus RTU/ASCII to Modbus TCP Converter
♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP
♦ Supports the connection of5 TCP clients simultaneously
♦ ODOT-S2E2 supports 2*RS485
♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422
♦ Each serial port supports Modbus masterand slave
♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway
♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway
♦ Supports one key reset
♦ Gateway working mode: Transparent transmission, address mapping
-
ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface to EtherNet
♦ Installed on the PPI/MPI/PROFIBUS communication port of PLC, generally without external powersupply
♦ Support Siemens S7 Ethernet communication drivers, including MicroWIN,STEP7, TIA Portal, WinCC etc.
♦ Integrated with Modbus-TCP server, Modbus data area can be automatically or edited to map to register S7-200/300/400
♦ S7TCP connection and Modbus-TCP communication can be realized simultaneously
♦ Up to 32 host computer connections are supported
♦ MPI to S7 Ethernet/Modbus-TCP converter
♦ Supports One-Key reset